Halon 1202 msds
WebFILE NO.: Incoming_SDS_Halon 2402_00 SDS DATE: January 2014 PAGE 4 OF 5 Inhalation may cause an increase in the sensitivity of the heart to adrenaline, which could … WebSep 16, 2024 · The Ozone Regulation also encompasses five additional ODS that are not covered by the Montreal Protocol. These ‘new substances’ are halon 1202, methyl chloride (MC), ethyl bromide (EB), trifluoroiodomethane (TFIM) and n-propyl bromide (n-PB). Producers, importers and exporters also have to report their activities for these new …
Halon 1202 msds
Did you know?
WebDibromodifluoromethane (Halon 1202), chemical formula CBr2F2, has a UL toxicity rating of 4. Halon 1202 is not recommended for aircraft use. Bromochlorodifluoromethane (Halon 1211), chemical formula CBrClF2, … WebDibromodifluoromethane is a mixed halomethane. It is a colorless non-flammable liquid. Along with Halons 1211, 2402, and 1301, it is one of the most effective fire extinguishers, …
WebFeb 9, 2012 · MATERIAL SAFETY DATA SHEET Halon 1211 (Fire Extinguishing Agent) Revision Date: February 9, 2012 Page 2 of 6 4. FIRST AID MEASURES Eyes … WebFeb 9, 2012 · MATERIAL SAFETY DATA SHEET Halon 1211 (Fire Extinguishing Agent) Revision Date: February 9, 2012 Page 2 of 6 4. FIRST AID MEASURES Eyes Immediately flood the eye with plenty of warm water for at least 15 minutes, holding the eye open. Obtain medical attention if soreness or redness persists. Skin Gently warm affected areas.
WebProduct Summary. Halon 1211 (Bromochlorodifluoromethane) is a streaming agent that is effective on all common types of fires (A, B, C). Production of this Halon ceased in 1994 as part of the Montreal Protocol, however, recycling of Halon 1211 allows it to remain in use. Halon 1211 is largely used as a streaming agent in portable, hand held fire ... WebKeywords Engine compartment fire extinguishant, Ventilation airflow, Agent distribution, Agent concentration, Halon 1202, Aircraft fires, Halon 1301, Combat damage, Aircraft engine nacelles. Fire tests and extinguishant concentration tests were conducted using a simulated portion of the F-16 aircraft engine compartment in the Aircraft Engine ...
WebAbout Halon 1202; Halon 1202 weighs 2.3063 gram per cubic centimeter or 2 306.3 kilogram per cubic meter, i.e. density of halon 1202 is equal to 2 306.3 kg/m³; at 15°C …
WebMay 22, 2024 · HALON 1301 H 3 R Clean Agents Halon 1301 Page 2 of 10 SECTION 3. COMPOSITION and INFORMATION ON INGREDIENTS Chemical Name %Chemical … hobart holding cabinethttp://www.halon.us/Halon-1301.pdf hro ft-710WebHalon 1202 was shown by these tests to be the most effective extinguishing agent but it is also the most toxic. Halon 1301, on the other hand, is the second most effective agent … hobart hock schedWebHALON 1211 H 3 R Clean Agents Halon 1211 Page 1 of 13 SAFETY DATA SHEET Prepared to U.S. OSHA, CMA, ANSI, Canadian WHMIS Standards, European Union … hro ft991aWebThe EPA is charged with enforcing the Clean Air Act and will therefore, have the responsibility of controlling the production of Halon. There have been several meetings called by the EPA with the purpose of identifying a process to develop a "recycling bank." Their concept is that recycling of Halon for essential use application is the environmentally hro ft-891WebFILE NO.: Incoming_SDS_Halon 1301_00 SDS DATE: January 2014 PAGE 4 OF 5 High vapor concentrations are irritating to the eyes and respiratory tract and may result in … hro ftdx-101mpWebMSDS AGNT-02 Halon 1211 QUICK IDENTIFIER Material Safety Data Sheet Common Name: (used on label and list) May be used to comply with OSHA’s Hazard Communication Standard, 29 CFR 1910. Standard must be consulted for specific requirements. Section 1-Manufacturer’s Name Kidde Aerospace Address 4200 Airport Drive, N.W. hroft